Springs |
Max. Operating
Temperature |
| 316 SS |
120°C (248°F) |
| Inconel 600 |
315°C (600°F) |
| Inconel X 750 |
537°C (1000°F) |
|
Spring Selection
For temperatures up to 315°C (600°F), Inconel springs will be
furnished as standard on all valves that are ordered with metal and Viton
seats. For service conditions above 315°C (600°F), Inconel X springs
should be specified. |